Specification Sheet:
Click to download specifications
2 Core x 7/0.85 (4mm2) + 7/0.67 Earth (2.5mm2). P.A.C.W.
V90 Insulated and 3V90 P.V.C. Sheathed.
Flat Twin & Earth Building Cable 450/750 Volt to AS/NZS 5000.2.
Oxygen Free Copper. RoHS Compliant.
TUV AUTHORISED MARKING: TUV022085EA
Construction
Conductor:
PHASE: 7 strands of 0.85 mm nom. Plain Annealed Copper to AS/NZS 1125 Class 2.
Max. D.C. resistance at 20C: 4.61 ohms / km.
EARTH: 7 strands of 0.67 mm nom. Plain Annealed Copper to AS/NZS 1125 Class 2.
Max. D.C. resistance at 20C: 7.41 ohms / km.
Insulation:
ACTIVE & NEUTRAL: Coloured V90 P.V.C. to AS/NZS 3808.
Nominal Diameter: 4.2 mm.
Nominal Wall Thickness: 0.8 mm.
EARTH: Nominal Diameter: 3.4 mm.
Minimum Wall Thickness: 0.7 mm.
Core Colours:
ACTIVE: 1. RED
NEUTRAL: 2. BLACK
EARTH: 3. LIGHT GREEN/YELLOW (in centre)
Laid parallel
Sheath: Coloured 3V90 P.V.C. to AS/NZS 3808. Flat configuration.
Nominal Dimensions: 6.4 x 14.8 mm.
Nominal Wall Thickness: 1.1 mm.
Identification: Printed on the sheath at maximum distance of 550mm: TYCAB AUSTRALIA 2017 V90 ELECTRIC CABLE 450/750V TUV022085EA BEM37085 2X4.0MM2 + 2.5MM2 E and Metre Marked.